Electro-Surgical unit can be used to execute monopolar and bipolar surgery in the many fields of application where high precision and reliability are essential, as in the endoscopic surgery.
  • Safe, Precise
  • User Friendly
  • Enhanced safety
  • A New Procedure technology
  • Light weight and compact design
  • For micro and minor procedure economical
In the uses of surgical diathermy, the technical ability of the unit combined with plain safety is of prime importance-both for the patient and the user. There must be no possibility of accidental, undesirable results in the use of AKS Electro-Surgical Units been developed.
The W is newly developed Electro-Surgical units of particular safety and reliability. The W as the most refined unit of its kind in the world.
Advanced Performance Features
Monopolar Cut Modes :
  • Pure Cut : Suitable for Micro and Minor procedure.
  • Blend-I : Preset blend I option for cutting with change in degree of hemostasis suited for Gyne procedures.
  • Blend-II : Preset blend II mode allows for cutting and simultaneous coagulation. Three Coag Modes:
  • Soft Mode: For low voltage coagulation, suitable for laparoscopic and delicate tissue work.
  • Forced Mode : This operating mode covers all the demands of standard coagulation. the surgeon can work quickly and effectively.
  • Spray : For non-contact large tissue area coagulation with minimum depth of necrosis.
Bipolar Two Modes :
  • Micro : For delicate tissue work by control desiccation without charring, adhesion or blancing of adjacent tissue (ophthalmic & neuro-surgery)..
  • Coag : High current low voltage pulsed bipolar output for high-pressure vessel sealing with ligation sure artery forceps. also suitable for bipolar needle ablation.
Advanced Safety Features
  • Patient Electrode Monitoring Technology monitors the quality and quantity of contact between the patient and the patient plate. If this contact is not proper the unit deactivates and alarms, thus eliminating risk of passive electrode site burns. It also deactivates the unit and alarms in case of any discontinuity in the patient plate cord.
  • Isolated RF output directs current to return back to the generator to reduce the risk of alternative site burns and to ensure patient safety in the case of any discontinuity in patient plate cord. This current has no reference to ground so it does not cause noticeable interference with the ECG monitor, Cardiac pacemaker etc.
  • Independent activation of unipolar and bipolar output to protect against inadvertent output from an idle accessory lying on or near the patient or surgical staff.
  • Class "2" leakage cancelling, a must for lengthy procedures like Cardiac surgery (CABG) etc.
  • Ergonomically designed trolley to house cautery and accessories.
  • Small and light weight portable unit.
  • Smart Modular Technology for fast and effective after sales support (service).
Weight & Dimension
Width :   475 mm
Height :   145 mm
Depth :   310 mm
Weight :   9 Kgs.
Output Waveforms
Bipolar :   330 KHz sinusoid
Monopolar Cut
Pure :   330 KHz sinusoid
Blend I :   330 KHz sinusoid
Blend II :   330 KHz sinusoid
Monopolar Coag.
Desiccate :   330 KHz Pulse
Fulgurate :   330 KHz Pulse
Low Frequency Leakage (50-60 Hz)
Source current, patient leads, all outputs tied together.
Normal polarity, intact chassis ground < 10 mA
Normal polarity, ground open < 50 mA
Reverse polarity, ground open < 50 mA
Sink current, 140V, applied, all inputs < 50 mA

Input Power Requirements
Operating range is 180 - 260 volts. Maximum current is 5 amperes (in cut, 240V nominal).
High Frequency Leakage

Bipolar Less than 50 mA rms
Monopolar Less than 100 mA rms

Power Readouts
Agree with actual power into rated load to within + 15% or 5 watts, whichever is greater. Dosage error monitor.
Audio Volume
The mode indicator tones are adjustable to a minimum level of 45 dB at 1 meter. The alarm tones are not adjustable and are set at 65 dB minimum at 1 meter.
CUT MACRO MACRO Crest Factor
Monopolar Cut 400 w / 500 Ohms 30 w / 500 Ohms 1.5
Blend I 250 w / 300 Ohms 30 w /300 Ohms 2.5
Blend Ii 200 w / 300 Ohms 30 w / 300 Ohms 3.0


COAG.      
Soft 100 w / 300 Ohms 30 w / 300 Ohms 5.0
Forced 200 w / 300 Ohms 30 w / 300 Ohms 5.0
Spray 100 w / 500 Ohms 30 w / 500 Ohms 8.0


BIPOLAR / COAG.      
Bipolar 70 w / 100 Ohms 30 w / 100 Ohm 5.0





Electro Surgical Generator With All Standard Accessories Along With Hand Switch And Bipolar




Specification
Indian Scientific Instruments Company
Enertech's E 400 Plus generators gives consistent and repeatable output as required by the surgeon in different types of surgeries.
E 400 Plus electro surgery generators gives best price performance ratio in similar class of generators offered by other manufacturers and can be widely used in procedures including Urology, GI, Gynaecologic, Orthopaedic, Thoracic and Plastic Surgery.
Performance Features
  • Pure Cut Two Blend Modes gives the surgeon varying degree of Hemostasis in the cut mode. Endo cut mode is provided for added flexibility.
  • True Spray Coag mode offers massive and rapid non-contact coagulation. Fulgurate Coag mode for sealing bleeders. Desiccate Coag mode for contact coagulation.
  • Micro / Macro Bipolar Modes provides controlled desiccation without charring,adhesion and blanching of tissues with bipolar cut and coag facility. Bipolar cut mode allows bipolar cutting operations.
  • Separate Monopolar and Bipolar R.F. output system allow two surgeons to work separately.
  • Absolutely Safe as Isolated RF Output provides direct current return to the generator significantly reducing the risk of alternate site burns.
  • Power-Limiting Output with Automatic Compensation Circuit provides more consistent performance over wide range of tissue impedance.
  • Patient plate monitoring system for high operational safety.
  • Micro Controller tissue response circuit network measures output impedance every 40 nano seconds and automatically adjusts the power.
  • Switching power supply accepts the wide range of input voltage from 150 to 270 Volts and hence keep the output constant throughout the range.
  • Highly Portable with weight of @ 5kg.
Technical Specification

  Max. Power (Watts) Rated Load (Ohms)
Operating Frequency 480 KHz -
Display 7 Segment digital -
Pure Cut 400W 500
Blend 1 250W 500
Blend 2 200W 500
Endocut 200W 500
Spray 120W 500
Fulguration 150W 500
Desiccation / Soft. 100W 500
Bipolar Coagulation Micro 80W 100
Bipolar Coagulation Macro 80W 500
Dimension (W x H x D) @ 4.5" x 10" X 11"
Weight @ 5 kg
Input Voltage 170 to 260VAC 50 Hz

Standard Accessories

Double Pedal Foot Switch (Monopolar) - 1 no.
Single Pedal Foot Switch (Bipolar) - 1 no.
S.S. Patient plate with cable o - 1 no.
Hand pencil disposable - 1 no.
Autoclavable chuck handle - 1 no.
Set of Electrode - 1 set.





Electro Surgical Generator With All Standard Accessories Along With Hand Switch And Bipolar




Specification
Indian Scientific Instruments Company
Enertech's E-300 generators gives consistent and repeatable output as required by the surgeon in different types of surgeries.
E-300 electro surgery generators gives best price performance ratio in similar class of generators offered by other manufacturers and can be widely used in procedures including Urology, GI, Gynaecologic, Orthopaedic, Thoracic and Plastic Surgery.
Performance Features
  • Pure Cut Two Blend Modes gives the surgeon varying degree of Hemostasis in the cut mode.
  • True Spray Coag mode offers massive and rapid noncontact coagulation. Force Coag for low voltage contact coagulation. Soft Coag mode delivers better coagulation with less depth of Tissue Necrosis.
  • Bipolar Mode provides controlled desiccation without charring, adhesion and blanching of tissues with bipolar cut and coag facility.
  • Poly p Cut divides cutting into interval of cuts and pauses, e.g. in Polypectomy or papillotomy. Coagulation occurs during each pause giving a supremely controlled cut with coagulation effects.
  • Six Programmable Modes for Plastic mode provides memory features for repeatable surgery parameters without the need for adjustments during each surgeries.
  • Separate Monopolar and Bipolar R.F. output system allow two surgeons to work separately.
  • Absolutely Safe as Isolated RF Output provides direct current return to the generator significantly reducing the risk of alternate site burns.
  • Patient plate monitoring circuit helps to prevent patient plate burns.
  • Micro Controller tissue response circuit network measures output impedance every 40 nano seconds and automatically adjusts the power.
  • Power-Limiting Output with Automatic Compensation Circuit provides more consistent performance over wide range of tissue impedance.
  • Switching power supply accepts the wide range of input voltage from 150 to 270 Volts and hence keep the output constant throughout the range.
  • Highly Portable with weight of @ 5 kg.
Technical Specification

Operating Frequency 480 KHz
Program modes 6
Display 7 Segment digital
Pure Auto Cut 300W
Blend 1 200W
Blend 2 150W
Spray 120W
Fulguration 150W
Desiccation / Soft. 80W
Bipolar Coagulation 80W
Dimension (W x H x D) @ 4.5" x 10" X 12"
Weight @ 5 kg
Input Voltage 170 to 260VAC 50 Hz

Standard Accessories

Double Pedal Foot Switch Monopolar - 1 no.
Single Pedal Foot Switch Bipolar - 1 no.
S.S. Patient plate with cable o - 1 no.
Hand pencil disposable - 1 no.
Autoclavable chuck handle - 1 no.
Set of Electrode - 1 set.





Electro Surgical Generator With All Standard Accessories Along With Hand Switch And Bipolar




Specification
Indian Scientific Instruments Company
Optima 300 generators gives consistent and repeatable output as required by the surgeon in different types of surgeries.
Optima 300 electro surgery generators gives best price performance ratio in similar class of generators offered by other manufacturers and can be widely used in procedures including Urology, GI, Gynaecologic, Orthopaedic, Thoracic and Plastic Surgery.
Performance Features
  • Pure Cut Two Blend Modes gives the surgeon varying degree of Hemostasis in the cut mode.
  • True Spray Coag mode offers massive and rapid noncontact coagulation. Pin Point Coag for small area coagulation.
  • Effective bipolar output gives excellent result In Laparoscopy.
  • Separate Monopolar and Bipolar R.F. output system allow two surgeons to work separately.
  • Absolutely Safe as Isolated RF Output provides direct current return to the generator significantly reducing the risk of alternate site burns.
  • Patient plate monitoring circuit helps to prevent patient plate burns.
  • Power-Limiting Output with Automatic Compensation Circuit provides more consistent performance over wide range of tissue impedance.
  • Micro Controller tissue response circuit network measures output impedance every 40 nano seconds and automatically adjusts the power.
  • Switching power supply accepts the wide range of input voltage from 150 to 270 Volts and hence keep the output constant throughout the range.
  • Highly Portable with weight of @ 7 kg.
Technical Specification

Operating Frequency 480 KHz
Display 7 Segment digital
Pure cut 300W
Blend 1 200W
Blend 2 150W
Blend 3 120W
Spray 120W
Pin Point 150W
Bipolar Coagulation 80W
Dimension (W x H x D) @ 4.5" x 12" X 12"
Weight @ 7 kg
Input Voltage 170 to 260VAC 50 Hz

Standard Accessories

Double Pedal Foot Switch Monopolar - 1 no.
Single Pedal Foot Switch Bipolar - 1 no.
S.S. Patient plate with cable o - 1 no.
Hand pencil disposable - 1 no.
Autoclavable chuck handle - 1 no.