Specification
 |
|
|
- Two Gases Rotameter Oxygen & Nitrous-Oxide
- Oxygen Flowmeter range 100 cc/min. to 10 liters/min., Nitrous Oxide
Flowmeter Range 200cc /min. to 12 liters/min.
- Standard Fresh Gas Outlet.
- Change Over System Open Circuit to Close Circuit.
- Emergency Flush Valve at front Panel connected to incoming O2 supply
- Goldman type Halothane Vaporizer.
- Parking space for two additional Vaporizers.
- Non-return cum Pressure Relief Valve minimize risk Of back flow of
gases.
- Blows off valve when pressure exceeds 200cm of Water column fitted.
- Provision to fit Ventilator.
- Provision to fit Carbon Dioxide Absorber.
- Extended platform at rear for two 'B' type cylinders.
- Table top made of Stainless Steel.
- Top Tray provided at eye level for keeping Monitoring Equipments.
- Maggill's or Bains circuit.
- One spacious Drawer on smooth runner.
- Four Castor Trolley with front two lockable Wheels.
- Pin Index Yokes two for Oxygen and two for Nitrous Oxide.
- High-efficiency Regulators for reliability two each for O2 & N2O.
Safety Features
- N2O cut off in case failure of Oxygen supply.
- Low Pressure Oxygen Audible Alarm.
Note : Cylinders, Circle Absorber, & other items
than the above mentioned specifications are supplied at extra cost.
Specification
- Easy access of Infant from all sides with thick acrylic collapsible
side panels
- Acrylic baby tray with Infant's Head up / down facility & foam
mattress.
- Provision for positioning X - ray cassette.
- S.S. Tray with slot to use under surface phototherapy.
- Swivelling warming source for taking X - ray
- Consist of CERAMIC INFRA RED / SILICON QUARTZ GLASS HEATER
- S.S. reflector with safety grill designed such to achieve uniform
temperature & easy cleaning without any electrical shock hazzard.
- Instrument tray, pole for Infusion pump & I.V. Stand.
- Examination lamp with sufficient illumination to access accurate
infant colour during procedures.
- M.S. Fabrication with powder coated paint.
- Mounted on castors for easy mobility.
Technical Specifications
 |
| Power Source |
230V AC, ± 10%, 50Hz |
| Light Source |
60 watts bulb to examine babies |
| Heater Capacity |
600 Watts |
| Power Consumption |
800 Watts at 100% Heater power |
|
 |
Salient Features :-
Servo Control Mode
Servo Control is an electronic feedback system which
functions as a thermostat to maintain a constant temperature at the site of
Skin Probe by regulating the heat output of Radiant Warmer. Maintaining a
constant abdominal Skin temperature between 36.5 & 37.0°C is the
simplest way to provide a " thermoneutral" environment, minimizing
the no. of calories needed to maintain normal body temperature &
reducing the risks of cold stress or overheating. Servo control is the only
acceptable method of heat regulation for the Infant cared for under a
Radiant Warmer.
Air Control Mode
Air Control is an electronic feedback system which
functions as a thermostat to maintain a constant temperature of baby cradle
by regulating the heat output of Radiant Warmer. It also acts as a WATCH DOG
as Air over temperature cuts off heater even if the Warmer is operating is
Servo Mode.
Manual Mode
The Manual mode allows the Warmer to be kept 'baby
ready' without nuisance alarms. When needed the Warmer provides safe
powerful & controlled warming to restore the temperature drop
experienced by the baby immediately after delivery.
Oxygen Administration
- Oxygen pressure adjustment regulator with hose pipe
- Humidifier bottle
- Reusable Silicon Patient tubing
- Oxygen flow meter with flow control facility (0-15 Lt / Min)
- Silicon Autoclavable Resuscitation Bag (250 ml) with Neonatal &
Infant mask.
Suction
Electrical operated Suction unit with presuure
adjustment facility (0-110 mm Hg) with unbreakable & autoclavable jar.
Inline Manometer
Monitors Oxygen pressure delivered through
Resuscitation Bag.
Intubation
Laryngoscope with 0 & 1 straight blades,
disposable E. T. Tubes with slip joints.
Models Available
- Infant Warmer (With Dual Probe)
- Infant Warmer (Skin / Manual)
- Infant Warmer (Air / Manual)
Item specification
 |
|
|
Standard 12-lead measure, 3-lead print, 1-lead
display on the screen. Input resistance: ?2.5M? Record resolution: Y axis ?8
points/mm, X axis?16 points/mm(speed of paper 25mm/s) Z ?8 points/mm( speed
of paper 50mm/s) Record paper: 48mm*15m Recording sensitivity standard
sensitivity 10mm/mV, allowance inaccuracies ±5% Sensitivity shift
amplifier has1/4 (2.5mm/Mv), 1/2 (5mm/mV), 1(10mm/mV), 2(20mm/mV) sensitive
shift when printing. The allowance inaccuracies range from 1 shift to other
shift is±5% Time constant: ?3.2s Temperature drift: between 5°C~40°C
and the baseline drift average is not more than 0.5mm/°C Disturbance
between channels: under standard sensitivity, each channel's
interdisturbance should be more than 0.5mm Auto lead mode and manual lead
mode Lead-off Detection with display indicator LCD display with English
interface, signs and numbers. Common Mode Rejection Ratio: ?60dB Device
storage and transportation condition Environment temperature range -20°C+55°C
Relative humidity range ?93% Atmosphere pressure range 500 hPa~1060hPa
Equipment operation environment condition Environment temperature range +10°C+40°C
Relative humidity range 30%~75% Atmosphere pressure range 700 hPa~1060hPa
Bandwidth For 10 Hz sine's ImV signal, the signal amplifier's input range
should be 100%, 0.5Hz~100Hz should be between 70%~105%.